Feature Guide References
None
Flash—Flash Width
Specifies the maximum length of a hookswitch signal sent from an SLT that can be recognised by the PBX as
a flash signal.
Value Range
8 ´ n (n=3–191) ms
Maintenance Console Location
3.46 [1-1] Slot—Card Property - EM type (KX-TDE series only)
Programming Manual References
None
Feature Guide References
None
Line Signal Setting—E&M-P Pulse Length—Seizure
Selects the length of a seizure pulse.
Value Range
150 ms, 600 ms
Maintenance Console Location
3.46 [1-1] Slot—Card Property - EM type (KX-TDE series only)
Programming Manual References
None
Feature Guide References
None
Line Signal Setting—E&M-P Pulse Length—Answer
Selects the length of an answer pulse.
Value Range
150 ms, 600 ms
3.46 [1-1] Slot—Card Property - EM type (KX-TDE series only)
PC Programming Manual