Rev. 01/2007
(adjustable with SP9-965-003) and the environment temperature is 17°C or
less.
Offset Value: Plain:
Normal/High Temp.
005 Specified the offset temperature for the plain paper in the low temperature. The
machine decreases this temperature when a job continues for 600 seconds
(adjustable with SP9-965-003) and the environment temperature is more than
17°C and 30°C or less.
Offset Value: M-Thick:
Low Temp.
006 Specified the offset temperature for the middle thick paper in the middle
temperature. The machine decreases this temperature when a job continues
for 600 seconds (adjustable with SP9-965-003) and the environment
temperature is 17°C or less.
Offset Value: M-Thick:
Normal/High Temp.
007 Specified the offset temperature for the middle thick paper in the middle
temperature. The machine decreases this temperature when a job continues
for 600 seconds (adjustable with SP9-965-003) and the environment
temperature is more than 17°C and 30°C or less.
Memory Clear (SP5-801)
The following tables list the items that are cleared. The serial number information,
meter charge setting and meter charge counters (SP8-581, 582, 583, 584, and
586) are not cleared.
5801
[Memory Clear]
5801 1 All Clear
SM
*ENG
[0 to 20 / 5 / 1 deg/step]
*ENG
[0 to 20 / 0 / 1 deg/step]
*ENG
[0 to 20 / 5 / 1 deg/step]
Resets all correction data for process control and
all software counters, and returns all modes and
adjustments to their default values.