Ricoh G133 Service Manual page 338

Table of Contents

Advertisement

Service Mode Table
temperature during the warm-up.
Stand-By: Pressure
012
Specifies the stand-by temperature for the pressure roller.
Pressure Target Energy
Saver
016
Specifies the temperature during the panel-off mode for the pressure roller.
The following SPs except SP1105-085 set the target operating temperatures of
the heating roller in various modes.
030 Plain: FC: Simplex
032 Plain: FC: Duplex
034 Plain: BW: Simplex
036 Plain: BW: Duplex
038 Thin: FC: Simplex
040 Thin: FC: Duplex
042 Thin: BW: Simplex
044 Thin: BW: Duplex
046 Thick 1: FC: Simplex
048 Thick 1: FC: Duplex
050 Thick 1: BW: Simplex
052 Thick 1: BW: Duplex
054 Thick 2: FC: Simplex
055 Thick 2: BW: Simplex
056 OHP: FC
057 OHP: BW
G133
* ENG
[90 to 150 / 150 / 1°C/step]
* ENG
[90 to 150 / 140 / 1°C/step]
*ENG
*ENG
[100 to 200 / 160 / 1°C/step]
*ENG
*ENG
*ENG
*ENG
[100 to 200 / 150 / 1°C/step]
*ENG
*ENG
*ENG
*ENG
[100 to 200 / 170 / 1°C/step]
*ENG
*ENG
*ENG
[100 to 200 / 170 / 1°C/step]
*ENG
*ENG
[100 to 180 / 165 / 1°C/step]
*ENG
[100 to 180 / 160 / 1°C/step]
5-16