Ricoh G133 Service Manual page 388

Table of Contents

Advertisement

Service Mode Table
Time
Adjust the time threshold for the line position adjustment (Mode b: adjustment
009
once). The timing for line position adjustment depends on the combinations of
several conditions. For details, see 'p.6-3 "Automatic Line Position
Adjustment"' in the "Detailed Section Descriptions" section.
Magnification
010 Adjusts the magnification threshold for line position adjustment. If the length of
the main scan is changed by this amount since the previous MUSIC, then
MSUIC is done again.
Temp. 2
Adjust the temperature change threshold for the line position adjustment
011
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions. For details, see 'p.6-3 "Automatic Line
Position Adjustment"' in the "Detailed Section Descriptions" section.
Time 2
Adjust the time threshold for the line position adjustment (Mode a: adjustment
012
twice). The timing for line position adjustment depends on the combinations of
several conditions. For details, see 'p.6-3 "Automatic Line Position
Adjustment"' in the "Detailed Section Descriptions" section.
2194
[MUSIC Execution Result] Line Position Adjustment: Execution Result
001 Year
002 Month
003 Day
004 Hour
005 Minute
006 Temperature
G133
*ENG
[1 to 1440 / 300 / 1 minute/step]
*ENG
[0 to 10 / 1 / 0.1%/step]
*ENG
[0 to 100 / 10 / 1°C/step]
*ENG
[1 to 9999 / 600 / 1 minute/step]
*ENG
[0 to 99 / 0 / 1 year/step]
*ENG
[1 to 12 / 1 / 1 month/step]
*ENG
[1 to 31 / 1 / 1 day/step]
*ENG
[0 to 23 / 0 / 1 hour/step]
*ENG
[0 to 59 / 0 / 1 minute/step]
*ENG
[0 to 100 / 0 / 1 page/step]
5-66
SM