Service Mode Table
Reload Correction
127
Temp.: M-Thick: Reload
Reload Correction
128
Temp.: M-Thick: Standby
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Fusing: Center
002 Fusing: Ends
003 Pressure
[Forced Ready Setting]
1108
Japan use only
001 ON/OFF
002 Target Voltage Ratio
003 Measured Voltage Ratio
004 Target Temperature
1109
[Fusing Nip Band Check]
001
Execute
G133
*ENG
[0 to 20 / 15 / 1°C/step]
*ENG
[0 to 20 / 10 / 1°C/step]
-
[–20 to 250 / - / 1°C/step]
The heating roller has two lamps. One
-
heats the center of the heating roller and
the other heats both ends of the heating
-
roller.
[0 or 1 / 0 / - ]
*ENG
0: OFF, 1: ON
*ENG
[85 to 100 / 92 / 1%/step]
*ENG
[70 to 120 / 100 / 1%/step]
*ENG
[110 to 155 / 155 / 1 deg/step]
Executes the nip band measurement
between fusing belt and pressure roller.
-
If the nip band width is not 8 mm, and
fusing is not good, replace the pressure
roller or install a new fusing unit.