Service Mode Table
011 Previous Temp.: Display
Previous Relative
012
Humidity: Display
Previous Absolute
013
Humidity: Display
[Color Registration Correction] FA
These values are the parameters for the manual and automatic line position
adjustment and are adjusted at the factory. However, you must input a value
2101
for SP2101-001 after replacing the laser optics housing unit. For details, see
"p.3-3 "Laser Optics Housing Unit"" in the "Replacement and Adjustment"
section. The value should be provided with the new laser optics housing unit.
001 Main Dot: Bk
002 Main Dot: M
003 Main Dot: C
004 Main Dot: Y
005 Sub Line: Bk
006 Sub Line: M
007 Sub Line: C
008 Sub Line: Y
2102
[Magnification Adjustment] DFU
Main Mag.: High Speed:
001
Bk
G133
[1 to 5 / – / 1 /step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Displays the previous temperature.
*ENG
[0 to 100 / – / 1°C/step]
Displays the previous relative humidity.
*ENG
[0 to 100 / – / 1%RH/step]
Displays the previous absolute humidity.
*ENG
[0 to 100 / – / 0.01 g/m
*ENG
*ENG
[–512 to 511 / 0 / 1 dot/step]
*ENG
*ENG
*ENG
*ENG
[–16384 to 16383 / 0 / 1 line/step]
*ENG
*ENG
These are results of the main scan
*ENG
length adjustment.
5-38
3
/step]