Ricoh G133 Service Manual page 508

Table of Contents

Advertisement

Service Mode Table
[Last PCU Mt: K] Last Drive PCU Motor: K
3513
Displays the last time that the PCU motors stopped.
These are used for process control execution timing.
001 Year
002 Month
003 Date
004 Hour
005 Minute
[Environment: Job End]
3514
Displays the environmental conditions for the last job.
These are used for process control execution timing.
001 Temperature
002 Relative Humidity
003 Absolute Humidity
[Execution Interval: Display]
Displays the current interval for process control execution.
3515
When the machine calculates the timing for process control, it uses a number
of conditions. These are the results after considering all the conditions.
001 Job End: Potential Control: BW
002 Job End: Potential Control: FC
003 Interrupt: Potential Control: BW
004 Interrupt: Potential Control: FC
3516
[Refresh Mode] DFU
G133
*ENG
[0 to 99 / 0 / 1/step]
*ENG
[1 to 12 / 1 / 1/step]
*ENG
[1 to 31 / 1 / 1/step]
*ENG
[0 to 23 / 0 / 1/step]
*ENG
[0 to 59 / 0 / 1/step]
*ENG
[-1280 to 1270 / - / 0.1°C/step]
*ENG
[0 to 1000 / - / 0.1%RH/step]
*ENG
[0 to 1000 / - / 0.1 g/cm
*ENG
[0 to 2000 / – / 1 page/step]
*ENG
[0 to 2000 / – / 1 page/step]
*ENG
[0 to 2000 / – / 1 page/step]
*ENG
[0 to 2000 / – / 1 page/step]
5-186
3
/step]
SM