001 Execute
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
2117
These SPs must be used when a new laser optics housing unit is installed or
when SC285 occurs. For details, see "p.3-3 "Laser Optics Housing Unit"" in the
"Replacement and Adjustment" section.
001 Pulse: M
002 Pulse: C
003 Pulse: Y
2118
[Skew Adjustment]
001 Execute: M
002 Execute: C
003 Execute: Y
[Skew Adjustment Display]
2119
Displays the current skew adjustment value for each skew motor.
001 M
002 C
003 Y
SM
This SP is used to check the ID sensors at
the factory. The results of this SP are
displayed in SP2140 to SP2145.
*ENG
[–50 to 50 / 0 / 1 pulse/step]
*ENG
*ENG
*ENG
Changes the current skew adjustment
values to the values specified with SP2117.
*ENG
These SPs must be used when a new laser
optics housing unit is installed or when
SC285 occurs. For details, see "p.3-3
*ENG
"Laser Optics Housing Unit"" in the
"Replacement and Adjustment" section.
*ENG
[–50 to 50 / 0 / 1 pulse/step]
*ENG
*ENG