Ricoh G133 Service Manual page 357

Table of Contents

Advertisement

temperature and Low humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: ML] Charge Roller AC Current Adjustment for ML
(Color)
2008
Displays/sets the AC current target of the charge roller for ML environment
(Meddle temperature and Low humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: MM] Charge Roller AC Current Adjustment for MM
(Color)
2009
Displays/sets the AC current target of the charge roller for MM environment
(Middle temperature and Middle humidity). DFU
001 Environmental Target: Bk
002 Environmental Target: M
003 Environmental Target: C
004 Environmental Target: Y
[Charge AC Current: MH] Charge Roller AC Current Adjustment for MH
2010
(Color)
SM
*ENG
[0 to 3 / 1.64 / 0.01 mA/step]
*ENG
[0 to 3 / 1.68 / 0.01 mA/step]
*ENG
*ENG
*ENG
[0 to 3 / 1.6 / 0.01 mA/step]
*ENG
[0 to 3 / 1.65 / 0.01 mA/step]
*ENG
*ENG
*ENG
[0 to 3 / 1.53 / 0.01 mA/step]
*ENG
[0 to 3 / 1.58 / 0.01 mA/step]
*ENG
*ENG
5-35