Ricoh G133 Service Manual page 527

Table of Contents

Advertisement

001 UCodeCtrClr
5501
[PM Alarm]
001 PM Alarm Level
5504
[Jam Alarm]
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
001
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
5505
error alarm counter decreases by "1" when an SC is not detected during a set
number of printed sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 -
5507
[Supply Alarm]
001 Paper Supply Alarm
002 Staple Supply Alarm
003 Toner Supply Alarm
SM
Clears all counters for users.
*CTL -
[0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999)
x 1000 ≥ PM counter
*CTL -
*CTL [0 to 255 / 40 / 100 pages /step]
*CTL -
0: Off, 1: On
0: Off, 1: On
0: Off, 1: On
5-205