Section 3: Operation

3.8.7 COMMUNICATIONS - Submenu

Defines and controls how single or multiple projectors are linked with each other and with a controlling device.
For detailed information refer to the Serial Command document provided in the Dealer Section of the Christie
Website, PN 020-100224-XX.
1.
Serial (RS-232 IN) Options
2.
Serial (RS-232 OUT) Options
3.
Serial (RS-422) Options
4.
Projector Address
5.
Network Routing
6.
Ethernet Settings
7.
Broadcast Key
8.
Front IR Enable
9.
Back IR Enable
10.
Wired Keypad Enable
• PROJECTOR ADDRESS
Enter a three-digit number (such as "001") to assign or change a number to the projector currently in use. If the
current projector already has a number assigned, that number will appear here (for example "004" in the menu
shown below. Numerical identity for projectors enables you to communicate with a single projector within a
multiple-projector application (see also P
assigning or changing the projector number, press E
used and you want to adjust the color for individual projectors to create one seamless image, you must assign
different numbers for each projector to allow switching back and forth between projectors while adjustments
are being made.
• NETWORK ROUTING
NOTE:
Not applicable for stand-alone projectors or simple serial networks with only one type of controller and
linking.
Separate - Select "Separate" (factory default) to keep RS-232, RS-422 and Ethernet messages on their
respective paths instead of being broadcast to the other types of ports, refer to
Figure 2-19 Connecting RS-232
RS-232 and RS-422 Joined - Messages originating from an RS-232 or RS-422 controller will be relayed to all
RS-232or RS-422 ports. Any Ethernet communication, however, will not.
RS-232 and Ethernet Joined - Messages to and from the RS-232 ports will also be relayed to the Ethernet
port, and vice versa. Any RS-422 communications will be isolated. In the case of multiple Ethernet sessions
over the single Ethernet connector, input on the RS-232 port will be relayed to all Ethernet sessions; however,
input from any Ethernet session will only be relayed to the RS-232 ports.
All Joined - All messages reach all ports, regardless of type in the case of multiple Ethernet sessions, input on
one Ethernet session will be relayed to all other Ethernet sessions as well as to the RS-232 and RS-422 ports.
3-36
Communications
Separate
1.
Separate
2.
RS-232 and RS-422 Joined
3.
RS-232 and Ethernet Joined
4.
All Joined
F
3-32 N
IGURE
to
Figure 2-24
ROJ
key in,
Figure 3-1 Remote
XIT
to cancel.
= Networks do not communicate with one another
= Serial networks are joined, but Ethernet is isolated
= RS-232 and Ethernet are joined but RS-422 is isolated
= Network communications travel all networks
R
L
ETWORK
OUTING
.
1.
Separate
2.
RS-232 and RS-422 Joined
3.
RS-232 and Ethernet Joined
4.
All Joined
Keypad). If you make a mistake in
NOTE:
When multiple projectors are being
IST
Section 2 Installation and Setup,