7.7.3 Weight
Maximum product weight (with lens removed)
Maximum shipping weight (includes packaging)
7.7.4 Operating Position
Horizontal
Inverted
Rotation
7.8
Reliability and Serviceability
7.8.1 Reliability
MTBF – excluding consumable components
Consumable components
7.8.2 Serviceability
MTTR, average
Time to replace any option card
Time to replace lamp
Time to replace projection lens
Time to replace air filter
7.9
Environment
7.9.1 Temperature/Humidity/Altitude
Operating temperature range
Storage temperature range
Humidity range
Operating Altitude
J Series 1000W and 1200W User Manual
020-100706-02 Rev. 1 (03-2014)
40kg (88lb.)
57kg (125lb.)
±15 degrees allowable rotation about lens axis
±15 degrees allowable rotation about lens axis
±180 degrees perpendicular to lens axis
12,500 hrs
Air filters, fans, lamps
30 min
1 minute maximum
1 minute maximum
30 seconds maximum
1 minute maximum
5 to 40 degrees C
-40 to 70 degrees C
10% to 80%, non condensing
10,000 ft. maximum
Section 7: Specifications
7-11