SERIAL OPTIONS - Submenu
• BAUD RATE
Determines the speed of communication to and from the projector on the RS-232 or RS-422 links. The
maximum rate for the RS-232 is 115200; for RS-422 it is 19200. Set the baud rate to match that of your
controlling device, such as your PC. Refer to the documentation for the controlling device to determine the
baud rate. In an existing network of projectors, if you discover that a projector has a different baud rate, use the
pull-down list and select the correct baud rate using the E
K
or R
A
EY
IGHT
• SERIAL FLOW CONTROL
Determines whether software flow control or no flow control is used when transmitting and receiving data on
the serial port.
ETHERNET SETTINGS - Submenu
NOTE:
Recommended for network administrators only.
• IP CONFIGURATION
Determines whether the IP Address is configured Static (manual) or Dynamic (HDCP). Dynamic (HDCP) is
the factory default setting.
• IP ADDRESS
Enter a valid and unique IP address for use on the network to which the projector is currently connected. This
address will overwrite any previous IP address such as the projector factory-defined default. It takes
approximately 10 seconds for the projector to respond at its new address.
• SUBNET MASK
Subnet Mask determines the subnet for the IP address and must be set manually.
• GATEWAY
This is the IP address of the gateway used to reach any non-local IP addresses; it must be set manually.
• TCP PORT
On some Ethernet networks, firewall restrictions may require that the port number of the projector be changed
from its default of 3002. If so, enter a new valid port number here. It is highly recommended not to use a port #
below 1000, as these ports are typically reserved for and used by common IP applications.
• HOST NAME
Set the hostname for the device
• DOMAIN NAME
Set the domain for the device
• MAC ADDRESS
Displays the MAC address of the projector (read-only)
BROADCAST KEYS
Use Broadcast Keys to relay all key presses received by the projector to all other projectors on the network.
FRONT IR ENABLED
Enable or disable the IR sensor on the front of the projector.
J Series 1000W and 1200W User Manual
020-100706-02 Rev. 1 (03-2014)
K
RROW
EY
. Serial communication is always eight data bits, no parity.
key. Do not scroll this control with L
NTER
Section 3: Operation
A
EFT
RROW
3-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds+8k-jHd7k-jDs+10k-jHd9k-j

Table of Contents