Lower values may cause false alarms.
1.4.17.2. Creating Intelli-Zone™ detection area(s)
To create Intelli-Zone™ detection area(s), do the following:
1. Place the cursor over the start point on the live view window
2. Hold the left mouse button down and drag to create a rectangular area
3. Let the mouse button go
4. Move/adjust the area if necessary. To delete a target area, click the area to select it, hold the left mouse button down
and drag the detection area off from the live view window. To erase all created areas, click Reset All Area.
1.4.17.3. Configuring Intelli-Zone™ detection area(s)
Each detection area has its own configuration and has to be saved individually. Up to 10 detection areas can be configured.
Each detection area can have its unique set of settings, including Area Name, Go to Preset #, Percent of Change, Dwell
Time, Control output, and Associated Channel. To switch between detection areas, select the chosen detection area by
clicking on the desired green box in the live view window. Selected detection area will be highlighted in red.
1. Select the specific detection area by clicking it in the live view window. Selected detection area is highlighted in red.
2. Enter Area Name for the created target zone in the Detection Zone frame. In the example above, the detection
area has been labeled "area1".
3. Select Go to Preset #. This is the position the PTZ camera will move to after the motion has been detected in the
selected detection area. Click the Browse button
configured in the Advanced Control tab of the SRX-Pro Control Center. (See Programming Presets section for more
information). In the example above, Channel #1 will move to Preset 3 when motion is detected on area1.
4. Set the Percent of Change between 1% and 99%. This value determines the amount of change that has to occur
in the image in order to be recognized. In the example above, the image change has to be at least 10% in order to
be recognized by Intelli-Zone.
5. Enter the Dwell Time (sec) (5-99 seconds). Dwell Time defines the number of seconds the selected channel will
remain in the Go to Preset position before returning to the Start Position. This Dwell Time also applies to the Control
output. In the example above, Channel #1 will remain in Preset 3 for 5 seconds before returning to Preset 1. Control
Output will remain active for 5 seconds after the motion has been detected on area1.
6. Assign the Control Output that will be triggered after the motion has been detected in the selected detection area.
Click the Browse button
Setup tab will be displayed. In the example above, Control 2 will be activated after the motion has been detected in
area1.
7. If desired, associate selected detection area with another channel:
a.
In the Associated with Channel frame, click the Browse button
channel from the list. Only channels activated in the Hardware Setup tab will be displayed.
b.
Click the Browse button
Presets section for more information).
Associated channel will assume this position when motion is detected by Intelli-Zone in the selected detection
area.
111
to select the desired preset from the list. All presets are
to select the desired control from the list. Only controls activated in the Hardware
in the Preset # field to select the desired preset from the list. (See Programming
Intelli-Zone™ Setup
in the Channel # field to select the desired