Hide thumbs Also See for NovaJet Pro 600e:
Table of Contents

Advertisement

3. Select the "Calibration Menu" from the Service Menu.
4. The Calibration Menu is shown in Figure 3-24 and is where all
the deadband tests are performed. Select "Deadband Test" to
perform the fast deadband test.
Figure 3-24. Calibration (Deadband) Menu.
5. When the plot is complete, select "Deadband" at the Calibration
Menu. This brings up the options menu for the fast deadband
adjustment. This menu is similiar to the menu depicted in
Figure 3-21.
The values for the fast deadband adjustment is
equivalent to 300 sections per inch. For every
incremented value, the print will move 1/300 of
an inch. Positive values move the middle segment
to the right, while more negative values move the
middle segment to the left.
6. Observe the plot and using either "Prev Option" or "Next
Option", rotate through the selections until one that seems
closer to the correct value is selected. Press "Ok" to accept the
selection and return to the Service Menu.
NovaJet PRO 600e Service Manual
NOTE
Maintenance
3-29