5. Slightly loosen the screws located on the back of the Y-arm
that secures the stabilizer to the Y-arm.
Damage may occur to the micrometer
gauge if the Carriage is moved without
lifting up on the measuring tip. This
action could also take the micrometer
out of alignment and foul the results of
the alignment.
6. While lifting up the measuring tip of the micrometer, slide
the Carriage to the left side of the stabilizer. Position it as
close to the screw as possible and drop the measuring tip onto
the platen. Do this a couple of times to ensure an accurate
reading.
7. Move the left end of the stabilizer bracket until a reading of
0.075" +/- 0.003" is observed. Read only the RED numbers on
the micrometer gauge.