2. Place gauge against left side of shaft assembly allowing
micrometer tip to rest directly on top of shaft. See Figure 3-12.
Zero the gauge (this is to become the reference point).
Figure 3-12. Measurement Positions for Slide Shaft.
3. Measure the right side (next to media alignment mark.) and
note the difference. Divide this amount by two.
4. Measure just off the center of the slide shaft and adjust the
center turnbuckle with an open ended wrench if required, for
the average value (the value found in step 3.) See Figure 3-13.
The NovaJet PRO 600e 60 inch model has two turnbuck-
les, so these need to be adjusted together for the center
position.