Setting The Caller Id Parameter Switches - Comdial G0408 Manual

Digital telephone system
Table of Contents

Advertisement

Digital Telephone System
2.19.1

Setting The Caller ID Parameter Switches

The Caller ID device has two banks of parameter switches located on its front panel. You must
set the switches of the S2 switch band in a certain manner to enable Caller ID operation.
Switches S2–1 through S2–5 set the baud rate, data bits, and parity, while switches S2–6, S2–7,
and S2–8 set the unit address for each device.
NOTE: If you are combining units (more than 8 lines are used), turn all switches in Dip
Switch S1 OFF except for switch 7. S1 switch 7 must be ON when combining units.
2 – 74 Installing The DSU
SWITCH S2–1
SWITCH S2–2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
* Set ON, ON (9600 baud) for DSU operation.
SWITCH S2–3
OFF
ON
*Set ON (8 data bits) for DSU operation.
SWITCH S2–4 SWITCH S2–5
OFF
OFF
ON
OFF
OFF
ON
ON
ON
* Set OFF, OFF (no parity) for DSU operation.
SWITCH S2–6
SWITCH S2–7
OFF
OFF
ON
OFF
OFF
ON
BAUD RATE
1200
2400
4800
9600*
DATA BITS
7
8*
PARITY
NO PARITY*
ODD
EVEN
EVEN
SWITCH S2–8
DEVICE
OFF
1
OFF
2
OFF
3
IMI66–107