Connecting Stations To The G0408 - Comdial G0408 Manual

Digital telephone system
Table of Contents

Advertisement

IMI66–107
2.5.4

Connecting Stations To The G0408

This table shows the color-coded connections for a G0408 common equipment cabinet.
Table 2–3: Connecting Stations To The G0408 Common Equipment Cabinet
25-Pair Connections
Wire Color
Pair
White-Blue
1
Blue-White
White-Orange
2
Orange-White
White-Green
3
Green-White
White-Brown
4
Brown-White
White-Slate
5
Slate-White
Red-Blue
6
Blue-Red
Red-Orange
7
Orange-Red
Red-Green
8
Green-Red
Red-Brown
9
Brown-Red
Red-Slate
10
Slate-Red
Black-Blue
11
Blue-Black
Black-Orange
12
Orange-Black
Black-Green
13
Green-Black
Black-Brown
14
Brown-Black
Black-Slate
15
Slate-Black
Yellow-Blue
16
Blue-Yellow
Yellow-Orange
17
Orange-Yellow
Yellow-Green
18
Green-Yellow
Yellow-Brown
19
Brown-Yellow
Yellow-Slate
20
Slate-Yellow
Violet-Blue
21
Blue-Violet
Violet-Orange
22
Orange-Violet
Violet-Green
23
Green-Violet
Violet-Brown
24
Brown-Violet
Violet-Slate
25
Slate-Violet
Two-Wire Connections
Clip
Pin No.
Pair
Term.
26
1
Signal Path
1
2
27
3
Signal Path
2
4
28
5
Signal Path
3
6
29
7
Signal Path
4
8
30
9
Signal Path
5
10
31
11
Signal Path
6
12
32
13
Signal Path
7
14
33
15
Signal Path
8
16
34
17
9
18
35
19
10
20
36
21
11
22
37
23
12
24
38
25
13
26
39
27
14
28
40
29
15
30
41
31
16
32
42
33
17
34
43
35
18
36
44
37
19
38
45
39
20
40
46
41
21
42
47
43
22
44
48
45
23
46
49
47
24
48
50
49
25
50
Digital Telephone System
Station Connections
Wire Color
Station
Green
10
Red
Green
11
Red
Green
12
Red
Green
13
Red
Green
14
Red
Green
15
Red
Green
16
Red
Green
17
Red
Spare Pairs
RS232
Data Port
A
RS232
Data Port
B
Installing The DSU 2 – 19
Location
TD
RD
CTS
SG
TD
RD
CTS
SG
Common Audible
Station 17 Audible
Power Fail Station

Hide quick links: