D Scanning
PROBLEM
• Squelch is open.
Programmed scan does not
stop.
• The same frequencies have been programmed
Programmed scan does not
start.
Memory scan does not start. • 2 or more memory channels have not been
• 2 or more memory channels have not been
Select memory scan does
not start.
• 2 or more memory channels with desired mode
Mode select memory scan
does not start.
∂F scan does not start.
• The center frequency for ∂F scan is not pro-
D Display
PROBLEM
• The dial lock function is turned ON.
The displayed frequency
does not change properly.
• The Set mode screen is selected.
• The internal CPU has malfunctioned.
POSSIBLE CAUSE
into both "1A–3A" and "1b–3b" of the scan edge
memory channels.
programmed.
designated as select channels.
have not been programmed.
grammed.
POSSIBLE CAUSE
MAINTENANCE
SOLUTION
• Set the [RF/SQL] control to the threshold
point.
• Program different frequencies into the "1A–3A"
and "1b–3b" scan edge memory channels.
• Program more than 2 memory channels.
• Designate more than 2 memory channels as
select channels for the scan.
• Program more than 2 memory channels with
the desired operating mode.
• Program the center frequency for a ∂F scan.
SOLUTION
• Hold down [SPEECH/LOCK] for 1 second to
turn OFF the function.
• Push [MENU] to exit the Set Mode.
• Reset the CPU.
17
REF.
pp. 44,
146
p. 148
p. 140
p. 151
1
p. 43
2
p. 152
3
4
REF.
p. 77
5
p. 161
6
p. 181
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
178