Chapter 6
Monitoring Settings
6.6

Transmission Test Execution

6.6
Transmission Test Execution
For SNMP Trap notifications or e-mail notifications, perform a transmission test to make sure that event noti-
fications are sent normally.
6.6.1

SNMP Trap Test

Perform the SNMP Trap test to check that the SNMP Trap can be sent from the ETERNUS DX Disk storage sys-
tem to the SNMP Manager.
The procedure to send trap test and to check the result is as follows:
1
Perform the test transmission of the SNMP Trap.
(1)
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
(2)
In [Category], click [Network].
The [Network] screen appears.
(3)
In [Action], click [Send SNMP Trap].
The [Send SNMP Trap Test] screen appears.
(4)
In the [Send SNMP Trap Test] screen, click the [Send] button.
A confirmation screen appears.
(5)
Click the [OK] button.
The test transmission of the SNMP Trap is performed.