Chapter 8
SAN Connection Settings
8.2
Server Connection Setup
When Checking Using the ETERNUS Multipath Driver
The following procedure explains how to check LUNs with the ETERNUS Multipath Driver.
1
Click the [Start] button, expand [ETERNUS Multipath Driver] from [All Programs], and open [ETERNUS
Multipath Manager].
2
Confirm that the same number of LUNs are displayed as the number of LUNs that are set.
If the LUNs for the ETERNUS DX Disk storage systems are recognized by the server, the devices (LUNs) in
the ETERNUS DX Disk storage systems are displayed under LUN and Disk Number.
The host interface (CA) numbers of the ETERNUS DX Disk storage system are displayed on ETERNUS
Multipath Driver as shown below.
CM#0 CA#0 Port#0 g CAID = 00
CM#0 CA#0 Port#1 g CAID = 01
CM#0 CA#1 Port#0 g CAID = 20
CM#0 CA#1 Port#1 g CAID = 21
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
CM#1 CA#0 Port#0 g CAID = 02
CM#1 CA#0 Port#1 g CAID = 03
CM#1 CA#1 Port#0 g CAID = 22
CM#1 CA#1 Port#1 g CAID = 23