Chapter 7
Power Control Setup
Perform power control settings as required.
Power control settings must be performed if the Auto Power function (AC automatic linkage mode) is ena-
bled, the Power Resume function (automatic power recovery mode) is enabled, the power synchronized unit
is connected, or the Wake On LAN function is used.
For details on the settings, refer to "Configuration Guide (Web GUI)".
7.1
Setup of the Auto Power Function and/or the Power Resume
Function
To automatically turn on the ETERNUS DX Disk storage system when AC power is supplied or when power is
restored after a power failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power
Resume function.
Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the ETERNUS DX Disk storage system is automatically turned on
when AC power is supplied.
The Auto Power function is disabled for the factory default setting.
Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS DX Disk storage system is automatically turned
on when the power supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
Table 7.1
shows how the ETERNUS DX Disk storage system operates when the Auto Power function and the
Power Resume function are enabled or disabled.
Table 7.1 ETERNUS DX Disk Storage System Operation According to the Settings of the Auto Power Function and the
Power Resume Function
Settings for the power control functions
Auto Power function is disabled
Power Resume function is disabled
Auto Power function is enabled
Power Resume function is disabled
Auto Power function is disabled
Power Resume function is enabled
FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Configuration Guide (Basic)
How the ETERNUS DX Disk storage system operates
The ETERNUS DX Disk storage system is not automati-
cally turned on even when AC power is supplied or
when power is restored after a power failure.
The ETERNUS DX Disk storage system is automatically
turned on when AC power is supplied.
The ETERNUS DX Disk storage system is not turned on
even when power is restored after a power failure.
The ETERNUS DX Disk storage system is not turned on
automatically even when AC power is supplied.
The ETERNUS DX Disk storage system is automatically
turned on when power is restored after a power failure.