Configuration-type Commands – xconfiguration / configuration.xml
ISDN
cont...
ISDN
PRI
ISDN
PRI
ISDN
PRI
ISDN
PRI
ISDN
PRI
ISDN
PRI
ISDN
PRI
D 13887.08
MAY 2008
NSFTelephony
Number: <0..31>
Defines what Service Facility to use for telephony if the NSFTelephony Mode is set to On.
xconfiguration isdn pri nsftelephony number: 8
Example:
Service profiles for AT&T (ref.1):
NSF Service
0 Disable
1 SDN (including GSDN)
2 Toll Free Megacom (800)
3 Megacom
6 ACCUNET Switched Digital Service (including Switched Digital International)
7 Long Distance Service (including AT&T World Connect)
8 International Toll Free Service (I800)
16 AT&T MultiQuest
23 Call Redirection Service
NSFVideoTelephony
Mode: <On/Off>
Enables/disables use of NSF for videotelephony. NSF = Network Service Facility
xconfiguration isdn pri nsfvideotelephony mode: on
Example:
NSFVideoTelephony
Number: <0..31>
Defines what Service Facility to use for videotelephony if NSFVideoTelephony Mode is set to On.
Example:
xconfiguration isdn pri nsfvideotelephony number: 8
SwitchType: <NI/ATT/Euro/Japan>
Selects the type of PRI switch the system is connected to.
xconfiguration isdn pri switchtype: ni
Example:
InitialRestart: <On/Off>
When restart is set to on the PRI interfaces will be reinitialized after boot.
xconfiguration isdn pri initialrestart: on
Example:
Alert: <On/Off>
If set to On, the system will respond with an alert message to all incoming setup messages. If set to Off (default) the system will respond with an alert
message only to the incoming setup message related to the initial channel. If, in addition, the PBX requires this signalling you will only get connected on
the first incoming channel.
xconfiguration isdn pri alert: on
Example:
ChanId: <On/Off>
Can be used to force sending of channel id information. When set to "on", the system will signal to the PBX which PRI channels is used for the call.
Default setting is Off. Note: This setting must be set to On, to work with an Ericsson MD110 PBX.
xconfiguration isdn pri chanid: on
Example:
92
TANDBERG 3000
MXP
& 6000
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Service profiles for Sprint (ref. 2):
NSF Service
0 Reserved
1 Private
2 Inwatts
3 Outwatts
4 FX
5 TieTrunk
Service profiles for MCI (ref. 3):
NSF Service
1 VNET/Vision
2 800
3 PRISM1, PRISMII, WATS
4 900
5 DAL