Fecc; Feedbackfilter; Ftp; G703 - TANDBERG Codec 3000 MXP Reference Manual

Guide for system integrators
Table of Contents

Advertisement

Configuration-type Commands – xconfiguration / configuration.xml
ExternalServices — G703
ExternalServices
Protocol: <HTTP/HTTPS>
Enables/disables secure management.
xconfiguration externalservices protocol: http
Example:

FECC

Mode: <On/Off>
Sets whether or not to allow the remote site to control the cameras connected to the system.
xconfiguration fecc mode: on
Example:

FeedbackFilter

Conference: <0..10>
Defines the Feedback filter (in seconds) for the Conference status element.
Example:
xconfiguration feedbackfilter conference: 4
FeedbackFilter
Call: <0..10>
Defines the Feedback filter (in seconds) for the Call status element.
xconfiguration feedbackfilter call: 2
Example:

FTP

Mode: <On/Off>
Enables or disables the systems embedded FTP server.
xconfiguration ftp mode: on
Example:

G703

PhysicalLayer: <E1/T1>
Selects whether the leased line is E1 or T1.
Example:
xconfiguration g703 physicallayer: e1
G703
Linecoding: <b8zsRestrict/b8zsNoRestrict>
Selects whether the Leased line is a 56kb network (restricted) or a 64kb network.
xconfiguration g703 linecoding: b8zsrestrict
Example:
G703
Callcontrol: <Manual/Auto>
When Auto is selected, the system will automatically initiate a connection as soon as it detects that the far end tries to make a call. This mode is also commonly known as "data
triggered" mode, because the existence of certain data patterns on the line triggers a connection.
When Manual is selected, you must explicitly issue a dial command to make the system connect to the far end system. Receiving an incoming call is not possible.
Example:
xconfiguration g703 callcontrol: auto
G703
Interface
D 13887.08
MAY 2008
StartChannel: <1..31>
Indicates the first E1/T1 channel the codec is allowed to use. This setting might be used if the E1/T1 line is shared with other equipment.
xconfiguration g703 interface startchannel: 6
Example:
Only relevant if using feedback (xfeedback over RS-232/Telnet or feedback
over HTTP).
The feedback filter lets the user configure the maximun frequency between
feedback updates. That means if data changes very rapidly, the control appplica-
tion will not receive feedback more frequent than every xth second. This will help
reducing the load on both the link and the control system, but some transition
information might be lost.