TANDBERG Codec 3000 MXP Reference Manual page 171

Guide for system integrators
Table of Contents

Advertisement

Status Information – xstatus /xstatus.xml
Call
cont...
Inactive
If status =
the following will be included
<Nothing>
Active
If status =
the following will be included
Protocol:
G711 / G722 / G722.1 / G728 / AAC-LD
Rate:
16...
Example:
*s Call 1 (status=Synced, type=Tlph, protocol=ISDN, direction=Incoming, logTag=5944):
CallRate: 64
RemoteNumber 1: "8733"
RemoteNumber 2: ""
RemoteSubAddress: ""
IncomingNumber: "8770"
IncomingSubAddress: ""
Mute: Off
Microphone: On
Duration: 127
MuteOutgoing: Off
Channels 1 (type=Incoming):
Rate: 64
Restrict: Off
Audio (status=Active):
Protocol: G711
Rate: 64
Channels 2 (type=Outgoing):
Rate: 64
Restrict: Off
Audio (status=Active):
Protocol: G711
Rate: 64
*s/end
Status information followed by a
D 13887.08
MAY 2008
*
will not be shown unless Detailed Level has been set to 2 – see
171
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
XACLI – Special commands – xpreferences
TANDBERG 3000
MXP
& 6000
MXP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Codec 6000 mxp

Table of Contents