Configuration-type Commands – xconfiguration / configuration.xml
StrictPassword — SystemUnit
StrictPassword: <On/Off>
If set to On, the system requires that the SystemUnit Password is minimum 8 characters long and that it includes both letters and digits.
xconfiguration strictpassword: on
Example:

Switch

Source: <1/2/3/4/5/6>
Select a physical input on the TANDBERG Video Switch.
xconfiguration switch source: 1
Example:
Switch
Configuration
Switch
Configuration
Switch
LogicalInput [1..5]
1 MainCam
2 AUX
3 Doc Cam
4 VCR
5 PC
Switch
LogicalInput [1..5]
1 MainCam
2 AUX
3 Doc Cam
4 VCR
5 PC

SystemUnit

Name: <S: 0, 49>
Defines the name of the system unit.
Example:
xconfiguration systemunit name: MySystem
SystemUnit
InternationalName: <S: 0, 49>
Defines the international name of the system unit – ASCII characters only!
xconfiguration systemunit internationalname: MySystem
Example:
D 13887.08
MAY 2008
Primary: <On/Off>
Default is on. If off, the codec will only do a basic setup of the primary chain and report what kind of cameras are connected. The codec will not set up
brightness, whitebalance, gamma etc. for each camera. Turn it off if an external control system handles all the configuration.
Example:
xconfiguration switch configuration primary: on
Secondary: <On/Off>
Default is on. If off, the codec will only do a basic setup of the secondary chain and report what kind of cameras are connected. The codec will not set up
brightness, whitebalance, gamma etc. for each camera. Turn it off if an external control system handles all the configuration.
xconfiguration switch configuration secondary: on
Example:
Mode: <On/Off>
Logical inputs are used when accessing inputs from the menu, remote control and FECC. There are five input buttons on the top of the TRC4 remote
control, and these can be remapped to any switch input you wish. The same five buttons are visible in the Presentation/Main Video menu, and these will
be remapped in the same manner. If the switch is connected with no special configuration, selecting "main cam" in the menu will give the current input
on the switch. Default value is Off.
Will set the logical input on the TANDBERG Video Switch to the given mode.
xconfiguration switch logicalinput 1 mode: On
Example:
Map: <1//2/3/4/5/6>
The Map [1..6] represents the switch inputs.
Remaps the five source buttons on top of the extended remote control to any switch input you wish. Will also remap inputs selected from the menu, and
change FECC accordingly. If mode for a key is on, the table entry will be used to specify which input on the switch to activate.
Example:
xconfiguration switch logicalinput 1 map: 1
115
TANDBERG 3000
MXP
& 6000
REFERENCE GUIDE FOR SYSTEM INTEGRATORS