The System Monitor Function

Activating System Monitor at a Staff/Duty or Patient Station

ProCare 6000 Operation Manual
When the system monitor is activated, all calls (normal, priority, emergency, and re-
minder recall) will flash and tone at the monitoring stations.
Depending on how your system is configured, the system monitor can be in master, staff,
or duty mode:
In master mode, a monitoring station will flash and tone for any calls placed from sta-
tions covered by the same base master as the monitoring station.
In staff mode, monitoring stations that have the same primary staff assignment as the
calling station will flash and tone.
Note:
This function does not operate if the ProCare 6000 system is equipped with version
5.XX video displays using MatchMaker ip.
If the call is not responded to within a preprogrammed time frame, monitoring stations
with a primary staff assignment that matches the calling station's alternate staff assign-
ment will flash and tone.
In duty mode, a monitoring station will flash and tone for any calls placed from sta-
tions in the same duty area as the monitoring station.
If your system is configured for staff or duty monitor mode, the system activates staff or
duty mode first. However, if all base masters covering the monitoring station are placed
off duty, the system reverts to master mode.
On the 4A24XX series patient stations, system monitor is activated automatically when-
ever presence is registered in the same room as the station (either manually by pressing
the button on a presence station, or automatically by wearing a staff IR locator badge).
It is turned off automatically when presence is no longer registered.
On staff/duty stations that are in staff mode, system monitor can be activated and deacti-
vated by pressing the DUTY button. The light on the button will illuminate when system
monitor is active.
On staff/duty stations that are in duty mode, system monitor is always on. (Pressing the
DUTY button does nothing. Its light is always illuminated.)
Additionally, when system monitor is activated, the red section of the corridor light illu-
minates (if so configured).