Activating Secrecy

Deactivating Secrecy

Appendix: Four-Gang Station Operations
When you do, this happens:
The station's CALL LED extinguishes.
The associated corridor light extinguishes.
Note:
When presence is registered, the section of the corridor light that corresponds to the
registered presence level stops flashing and steadily illuminates.
The reminder recall disappears from the base master display and the video display
(if present).
The reminder recall disappears from stations where the system monitor function is ac-
tive or at staff/duty stations where presence is registered.
Press the station's SECRECY button to place the station in secrecy mode. See Figure A-3
on page A-4. When you do, this happens:
The station's SECRECY LED illuminates to confirm secrecy mode.
The base master attendant cannot hear any sound from the station.
Note:
When a station is in secrecy mode, the person at the station can hear the base master
attendant, but the attendant cannot hear the other person. Secrecy mode can be suspended
by placing a call from the station or from an attached pillow speaker. Secrecy is automati-
cally reinstated when the call ends, and remains activated until it is canceled. See
Deactivating Secrecy below.
Press the station's illuminated SECRECY button to deactivate the secrecy function on a
patient or staff/duty station. See Figure A-3 on page A-4. When you do, this happens:
The station's SECRECY LED extinguishes.
The secrecy function is deactivated.
Note:
Secrecy is temporarily suspended when a call is made from the room. It is automatically
reinstated when the call is completed, until secrecy is canceled.