Single and Dual Patient Stations

The CODE Button

4-2
The dual patient station is normally mounted in the head wall between the patient beds.
It is pictured in Figure 4-2.
CALL
ALIGN CONNECTOR TAB

Figure 4-2: Model 4A2486 Dual Patient Station

Note:
If your system has custom stations, the button descriptions in this manual may not
match your stations. For example, the CODE button on your station may read "code
blue." Note these customizations in the manual's margins.
Press this button to send a code blue emergency call to the base master station. (Dual pa-
tient stations will send two calls, one left bed and one right bed, when this button is
pressed.) This causes the following to happen:
The light on the CODE button illuminates to confirm call placement.
The patient station beeps eight times.
The associated corridor light illuminates and flashes at a designated rate (default is fast
flash amber).
The call appears on the base master display.
Tones sound at the base master and at stations where the system monitor function is
active.
AUX
BED
CODE
AUX
ALIGN CONNECTOR TAB
AUX
CALL
STAFF
CANCEL
ProCare 6000 Operation Manual