28.6

Restoring the System

Turn on the CB switches of the dedicated power distribution unit (PDU)
mounted on the rack for expanded connection.
Execute the diagxbu command to diagnose the crossbar cables.
XSCF>   diagxbu -y -b 00 -t 01
XSCF>   diagxbu -y -b 00 -p 02
Execute the showlogs command to confirm that the system is operating
normally.
XSCF>   showlogs error
Start the entire system.
Close the rack door.
When the system board of the chassis connected with the crossbar cables
is not incorporated into the physical partition, or when the incorporated
physical partition is powered off:
When the system board of the chassis connected with the crossbar cables
is incorporated into the physical partition, and the physical partition is
powered on:
Chapter 28 Maintaining the Cable Kit of the Crossbar Box