Installing An Xscf Dual Control Cable - Fujitsu SPARC M10-4 Service Manual

Servers
Hide thumbs Also See for SPARC M10-4:
Table of Contents

Advertisement

27.5
Installing an XSCF DUAL Control
Cable
Attach the supplied connection destination label to the replacement XSCF
DUAL control cable.
Connect the XSCF DUAL control cable to SPARC M10-4S or the crossbar box.
Note -
27.6
Restoring the System
27.6.1
Active/Hot maintenance
Disconnect and then connect the XSCF unit.
Return to the replacefru command operation of the XSCF firmware to confirm
that the XSCF unit of the crossbar box has been incorporated into the system.
Execute the showstatus command to confirm that the FRU is operating
normally after the completion of maintenance.
XSCF>   showstatus
Execute the showhardconf command to check the hardware configuration
Chapter 27 Maintaining the XSCF DUAL Control Cables
413