15.6.1
Active/Cold maintenance
Note -
Note -
Connect all the power cords to the PSU backplane unit of the chassis
requiring maintenance.
Note -
Return to the operation of the XSCF firmware replacefru command to confirm
that the chassis has been incorporated into the system.
Execute the diagxbu command to diagnose the crossbar cables.
XSCF> diagxbu -y -b 00 -p 02
Execute the showlogs command to confirm that the system is operating
normally.
XSCF> showlogs error
Incorporate the chassis, in which the operation panel requiring maintenance
is mounted, into the physical partition.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
294