        Hypervisor         :   0.21.3
XSCF                     :   02.01.0001
CMU   BACKUP
#0:   02.01.0001
#1:   ..
XSCF>
Execute the showlogs command to confirm that the system is operating
normally.
XSCF>   showlogs error
Execute the testsb command to confirm that the CPU memory unit requiring
maintenance is normally recognized.
XSCF>   testsb -v -y -s 00-0
Execute the showstatus command to confirm that the CPU memory unit is
operating normally after maintenance.
XSCF>   showstatus
Execute the showhardconf command to check the hardware configuration
and the status of each component.
XSCF>   showhardconf
Execute the showdate command to confirm the XSCF time.
XSCF>   showdate
If the XSCF time is different from the current time, execute the setdate
command to set the time.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014