#   cfgadm -a
Ap_Id                               Type                   Receptacle       Occupant           Condition
BB#0-PCI#0                     pci-pci/hp       connected         configured       ok
Execute the cfgadm -c command to release the PCIe card requiring
maintenance from the logical domain.
#   cfgadm -c unconfigure  Ap_Id
Execute the cfgadm -c command to stop the power supply to the PCIe card
requiring maintenance.
#   cfgadm -c disconnect  Ap_Id
Execute the cfgadm -a command to confirm the status of the PCIe card again.
#   cfgadm -a 
Ap_Id                               Type                   Receptacle       Occupant           Condition  
BB#0-PCI#0                     pci-pci/hp       disconnected   unconfigured   ok
Execute the cfgadm -x command to cause the ATTENTION LED on the PCIe
card cassette requiring maintenance to blink.
#   cfgadm -x led=attn,mode=blink  Ap_Id
13.4.2
Active/hot maintenance (with DR)
Note -
Note -
Open the rack door.
Confirm the hardware and software configurations.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014