27.3
Enabling the Removal of an XSCF
DUAL Control Cable
Caution -
27.3.1
Active/Hot maintenance
Open the rack door.
Log in to the XSCF shell.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
Confirm the hardware and software configurations.
Execute the switchscf command to switch the master XSCF to a standby
XSCF.
XSCF>   switchscf -t Standby
Execute the replacefru command to release the XSCF unit of the crossbar box
requiring maintenance from the system.
XSCF>   replacefru