Note -
13.7.1
Active/hot maintenance (with PHP)
Display the Oracle Solaris super-user prompt.
Execute the cfgadm -c command to start the power supply to the PCIe card
requiring maintenance.
#   cfgadm -c connect  Ap_Id
Execute the cfgadm -c command to incorporate the PCIe card requiring
maintenance into the logical domain.
#   cfgadm -c configure  Ap_Id
Execute the cfgadm -a command to confirm that the PCIe card requiring
maintenance has been incorporated into the logical domain.
#   cfgadm -a
Ap_Id                               Type                   Receptacle       Occupant          
Condition
BB#0-PCI#0                     pci-pci/hp       connected         configured       ok
Execute the svcadm disable command to disable the hotplug service.
#   svcadm disable hotplug
If you deleted the virtual device and the virtual service in
maintenance (with
note of and reassign them to the guest domain.
VM Server for SPARC Administration Guide
PHP)," add them based on the information you made a
Chapter 13 Maintaining the PCI Express Cards
"13.4.1 Active/hot
Oracle