XSCF>   switchscf -t Standby
The   XSCF   unit   switch   between   the   Master   and   Standby   states.  
Continue?   [y|n]   : y
Log in to the XSCF again.
Execute the showpparstatus command to confirm the operating condition of
the physical partition.
XSCF>   showpparstatus -p 0
PPAR-ID                 PPAR   Status
00                           Running
Execute the showdomainstatus command to confirm the operating condition
of the logical domain.
XSCF>     showdomainstatus -p 0 
Logical   Domain   Name       Status  
primary                               Solaris   running
guest0                                 Solaris   running
guest1                                 Solaris   running
domain01                             Solaris   running
Connect to the control domain console of the physical partition.
Execute the ldm list-domain command to confirm the operating condition of
the logical domain.
#   ldm list-domain
NAME                           STATE             FLAGS       CONS         VCPU     MEMORY       UTIL     UPTIME
primary                     active           -n-cv-     UART         14         8G                 64%     2h   54m
guest0                       active           -n----     5000         16         8G                 42%     2h   54m
guest1                       active           -n----     5001         16         8G                 11%     2h   54m
domain01                   active           -n----     5002         16         8G               7.3%     2h   54m
Execute the ldm list-devices -a command to check the usage status of the
resource.