When the system is configured with a software RAID
When the system is configured without either a hardware RAID or software
RAID
Return to the operation of the cfgadm(1M) command of Oracle Solaris
super-user prompt and confirm that the number of internal disks has increased.
# cfgadm -a
Execute the cfgadm(1M) command to incorporate the internal disk requiring
maintenance into Oracle Solaris.
# cfgadm -c configure Ap_ID
Execute the cfgadm(1M) command to confirm that the internal disk requiring
maintenance has been incorporated.
# cfgadm -a
Close the rack door.
12.6.2
Active/hot maintenance (with DR)
Execute the testsb command to confirm that the internal disk requiring
maintenance is recognized.
XSCF> testsb -v -y -p 00-0
Incorporate the chassis, in which the internal disk requiring maintenance is
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014