and the status of each component.
XSCF> showhardconf
Execute the switchscf command to switch the standby XSCF to the master
XSCF.
XSCF> switchscf -t Active
Close the rack door.
27.6.2
Active/Cold maintenance
Connect all the power cords to the PSU backplane unit or power supply unit
of the chassis requiring maintenance.
Note -
Return to the operation of the XSCF firmware replacefru command to confirm
that SPARC M10-4S has been incorporated into the system.
Execute the showstatus command to confirm that the XSCF DUAL control
cable is operating normally after the completion of maintenance.
XSCF> showstatus
Execute the showhardconf command to check the hardware configuration
and the status of each component.
XSCF> showhardconf
Incorporate the chassis connected to the XSCF DUAL control cable requiring
maintenance into the physical partition.
Close the rack door.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
414