Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
Confirm the hardware and software configurations.
Stop the entire system.
Turn off the circuit breaker switches (CB switches) of the dedicated power
distribution unit (PDU) mounted on the rack for expanded connection.
23.4

Removing the Operation Panel

Caution -
23.4.1
Accessing the operation panel
Check the BB-ID switch on the operation panel and record the BB-ID set for
the crossbar box requiring maintenance.
Remove the front cover of the crossbar box.
Remove all the fan units.
Loosen the two screws (A in the figure) securing the upper cover and then
slide the right and left stoppers (B in the figure) inwards. Then, remove the
upper cover (C in the figure).
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014