Confirm the hardware and software configurations.
Power off the physical partition requiring maintenance.
Execute the replacefru command to release the power supply unit requiring
maintenance from the system.
XSCF>   replacefru
10.3.3
Inactive/Cold maintenance
Note -
Open the rack door.
Log in to the XSCF shell.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
Confirm the hardware and software configurations.
Power off the physical partition requiring maintenance.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF>   replacefru
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014
204