Authentication Server - Axis E100 User Manual

Network cd-rom server
Table of Contents

Advertisement

Section 4: NetWare (NCP)
Installation Errors in
NetWare NDS
Installation as a
Bindery Server
56
If you experience problems when installing your StorPoint CD in a NetWare
NDS network, errors that occur will be written to a file named
located in the
System/ServerProperties
on the Event Log page within the StorPoint CD Web interface.
This table comprises a summary of error messages:
Error
Installation failed: NDS tree not found
Installation failed: Administrator object
missing
Installation failed: Administrator
password is incorrect
Installation failed: Server context not
found
Installation failed: Insufficient rights to
create server object
Installation failed: NDS Server object
already exists
Installation warning: Could not extend
NDS Schema. User xxxxx doesn't have
SUPERVISOR rights to the [Root] object.
Installation warning: Could not extend
NDS Schema (class 1)
Installation warning: Could not extend
NDS Schema (class 2)
Installation warning: Could not extend
NDS Schema (attribute)
If used as a bindery server, no specific installation is required prior to using and
accessing the StorPoint CD. However, it is recommended that you specify the

authentication server.

folder. You can display the log file
Description
The server could not find the NDS tree. Verify the spelling.
The server could not find the user object specified in the
NDSAdminName
parameter. Verify that you use the
correct format, e.g. admin.acme. Verify the spelling.
The password supplied in the
NDSAdminPassword
password could not be used to login as the user in the
NDSAdminName
parameter. Verify the spelling.
The context specified in the
NDSServerContext
parameter was not found. Verify the spelling.
NDSAdminName
The specified user in the
does not have sufficient rights to create the server object in
the specified context.
You have tried to install the server on top of an existing
NDSInstall
server object. Set the
to overwrite the existing object.
The administrator who is trying to install the server has
insufficient rights for adding the schema extension. Specify a
NDSAdminName
with Supervisor rights to the [Root]
object.
These errors are the result of insufficient rights of the
administrator trying to install the server. Specify a
NDSAdminName
with Supervisor rights to the [Root]
object.