Appendix A Parameter List; The Configuration File - Axis E100 User Manual

Network cd-rom server
Table of Contents

Advertisement

Appendix A Parameter List

The Configuration File

Note:
Parameter name
[Server]
HardwareAddress
Date
Time
FactoryDefaults
Restart
TimeZone
TimeSyncSource
ServerPassword
Shut Down
NetworkSpeed
NetworkDuplex
CDWritePassword*
[SCSI]
SCSITermination
JukeBoxLockTime
Disconnect_Reselect
BusMode
[IDE]
JukeBoxLockTime
[IP]
AXIS StorPoint CD E100 User's Manual
This section includes the StorPoint CD parameter list. It also explains the
StorPoint CD directory structure and how to edit the configuration settings.
This table shows the parameter list stored in the
System/ServerProperties
The middle column shows the default values, when applicable. The right-hand
column gives a brief description of the parameters.
Parameters denoted by an asterisk (*) are not available in the Basic versions

of the StorPoint CD.
Value
= 00:40:8c:11:00:86 The StorPoint CD hardware address. Default is the serial number.
= 99-11-01
= 12:00:00
= no
= no
= UTC
= NDS
= pass
= no
= auto
= auto
=
= on
= 0
= on
= Asynchronous
= 0
config.ini
folder, see the "Directory Structure " on page 116.
Description
You can set a Locally Administrated Address. The value shown is
an example only.
yy-mm-dd, enter the date followed by ! to set manually
hh:mm:ss, enter the time followed by ! to set manually
Set to configuration, volumeProperties or all.
Set to yes to restart the StorPoint CD.
Must be set to the time zone that the StorPoint CD is operating in.
Refer to "Time Zone Parameter Values " on page 115.
Specifies the time source for the StorPoint CD. Set to NDS for
NetWare IPX. Set to NTP for NetWare PureIP, UNIX and SMB
over TCP/IP. Note that you will need third party software on your
Windows NT server to obtain support for NTP. Set to None for
manually setting the time.
The Supervisor, Administrator or Root user password used for
basically all protocols; i.e. HTTP, NetWare bindery, SMB user level,
SNMP and FTP. Once written into the configuration file, the
password will not be shown but replaced with *'s, representing
each letter of the password.
Set to yes to shut down the StorPoint CD.
The network speed. Set to 10, 100 or auto. Default is auto, which
means that it is automatically detected by the StorPoint CD.
The network duplex. Set to full, half or auto. Default is auto, which
means that it is automatically detected by the StorPoint CD.
Optional password used for protecting the Recordable Discs page.
Set to yes or no.
Always on.
Specifies the maximum duration for a data read operation during
multiple access requests to prevent disc changer fluttering. Default
is 0 seconds which disables the function.
Set to off to disable the disconnect/reselect function in the disc
drives.
Specifies the transfer mode on the SCSI bus: Asynchronous,
Synchronous, Fast-10 or Ultra.
Specifies the maximum duration for a data read operation during
multiple access requests to prevent disc changer fluttering. Default
is 0 seconds which disables the function.
Appendix A: Parameter List
file located in the
111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storpoint cd e100

Table of Contents