6)
When you copy a port, the smart link/monitor link group member information configured on the port
will not be copied to other ports.
7)
If a single port is specified as a member of a smart link/monitor link group, you cannot execute the
lacp enable command on this port or add this port into other dynamic link aggregation groups,
because these operations will make this port become a link aggregation group member.
8)
If no control VLAN is configured for flush message processing, the device will forward received
flush messages without processing them.
9)
If the control VLAN for receiving flush messages configured on an associated device is different
than the one for sending flush messages configured on the corresponding Smart Link device, the
device will forward received flush messages without processing them.
10) In the static or manual link aggregation group which serves as a smart link group member, if a
member port can process flush messages, this function cannot be synchronized to the other ports
in the aggregation group automatically, that is, the other member ports in the aggregation group
cannot process flush messages. The function of processing flush messages must be manually
configured for each port in the aggregation group.
11) The VLAN configured as a control VLAN to send and receive flush messages must exist. You
cannot directly remove the control VLAN. When a dynamic VLAN is configured as the control VLAN
for the smart link group, this VLAN will become a static VLAN, and the prompt information is
displayed.

Displaying and Maintaining Smart Link

To do...
Display the information of a smart
link group
Display the statistics information of
flush messages received and
processed by the current device
Clear flush message statistics

Smart Link Configuration Example

Implementing Link Redundancy Backup

Network requirements
As shown in
Figure
Switch E support Smart Link. Configure Smart Link feature to provide remote PCs with reliable access
to the server.
display smart-link group
{ group-id | all }
display smart-link flush
reset smart-link packets
counter
1-3, Switch A is an H3C S5100-SI/EI series Ethernet switch. Switch C, Switch D and
Use the command...