PCI expansion slot definitions (DL380 G7)
Always install an InfiniBand PCIe HCA in slot 4 of this server.
Secondary
(slot - form factor)
4 - FL/FH
5 - LP
6 - LP
Notes:
•
"Primary" denotes the risers are installed in the primary riser connector.
•
"Secondary" denotes the risers are installed in the secondary riser connector.
•
Installing the risers listed in the table above in either the primary or secondary riser connectors
determines the form factor of the PCI cards supported by those risers.
•
FL/FH denotes full-length, full-height. HL/FH denotes half-length, full-height. LP denotes low profile.
•
The PCIe2 x16 riser supports a maximum power of 150 W with an HP power cable. This cable must be
used for PCIe card wattages greater than 75 W.
HP ProLiant Rack Servers (AMD Opteron)
Several HP ProLiant AMD Opteron servers are supported in HP Cluster Platform solutions. This section
presents information for the HP ProLiant servers that are used in HP Cluster Platform solutions only. The
content in this section includes the following additional information for the HP ProLiant AMD Opteron servers:
•
Front and rear views
•
InfiniBand HCA PCI slot assignment
•
Specific cable management instructions, if necessary
•
HP Cluster Platform specific maintenance instructions, if applicable
HP ProLiant DL165 G6 Server
The HP ProLiant DL165 G6 Server is used as a control node and a compute node in HP Cluster Platform
configurations.
Primary
PCIe2 riser
slot description
(slot - form factor)
1 - FL/FH
PCIe2 x16 (8,4,1) PCIe2 x16
2 - HL/FH
PCIe2 x8 (4,1)
3 - HL/FH
PCIe2 x8 (4,1)
PCIe2 x16 riser
PCIe2/PCI-X riser
slot description
slot description
PCI-X 64 bit/133 MHz
(16,8,4,1)
—
PCIe2 x16 (8,4,1)
—
PCIe2 x8 (4,1)
HP ProLiant servers (rack) 27