Nozzle Control Sequence (Vacuum Cleaner) - AND Multi Function Weighing Indicator AD-4402 Instruction Manual

Multi function weighing indicator
Table of Contents

Advertisement

7.3.8.
7.3.8.
Nozzle Control Sequence (
Nozzle Control Sequence (vacuum cleaner
7.3.8.
7.3.8.
Nozzle Control Sequence (
Nozzle Control Sequence (
The nozzle is used for filling a bottle with a liquid or powder. The procedure inserts the
nozzle into the bottle automatically using the signal "nozzle down" before the
weighing, weighs it and removes the nozzle when dribble flow is finished. Therefore,
the result (comparison) of weighing is not affected.
Advise
In case of using the nozzle control sequence
[5q f-12]
In case of using the timer to ready nozzle.
[5q f-32]
In case of using the nozzle down
[0utf-nn]
In case of compare it after shifting up nozzle
[5q f-12]
AD-4402
[Function] - [Function setting] - [Sequence] - [Control] - [Nozzle control]
[Function] - [Function setting] - [Sequence] - [Timer - [Batch start delay
timer]
Nozzle down
nn: terminal number of the I/O.
[Function] - [Function setting] - [Control I/O] - [Output]
[Function] - [Function setting] - [Sequence] - [Control] - [Nozzle control]
Displayed value
0
Start command, Input
Inserting nozzle, Output
Start delay timer
Full flow, Output
Medium flow, Output
Dribble flow, Output
Eval delay timer
Stable, Output
Batch finish, Output
vacuum cleaner) ) ) )
vacuum cleaner
vacuum cleaner
Insert nozzle when receiving start signal
Compari s on
Page 53
Removing nozzle when dribble finish