Sq F—Weighing Sequence Functions
The SqF functions are available only for the mode specified in the note column and each mode name
is described as shown below. Not specified functions are available for all the weighting sequences.
Auto: Built-in automatic program mode
Loss: Loss-in-weight mode
Note
Function #
SqF-01
1
Internal count
2
Display count
Sq F-02
0
No Automatic accumulation
1
Accumulates only acceptable
2
Accumulates all values
Sq F-03
Batch
0
No automatic free fall compensation
1
Moving average of last four times
Sq F-04
Batch
Automatic free fall compensation is made if the measured weight is within the final +/-
automatic free fall effective width.
Sq F-05
Auto
If Flow-time is shorter than the setting, the preset Free Fall is applied to the weighing instead of
the Auto-Free-Fall compensation.
Sq F-06
Auto
1
Customer programmed control mode
2
Synchronized with Batch Finish Output
Sq F-07
Auto
0
Not required
1
Required
Sq F-08
Auto
This is the number of how many times supplementary flow is done.
Sq F-09
Auto
Sq F-10
Auto
Sq F-11
Auto
Sq F-12
Auto
Sq F-13
Auto
Batch: Batch-weighing mode
Nozzle: Nozzle controlled weighing mode
Function name
Selection of comparison weight
Automatic accumulation
Automatic free fall compensation
Automatic free fall
effective width
Unstable Dribble
Flow Time
Overlimit/ underlimit operation
Stability at judgment
Maximum number of
supplementary flow
times
Batch start wait timer
Full-flow comparator
inhibitor timer
Medium-flow
comparator inhibitor
timer
Dribble-flow
comparator inhibitor
timer
Judgment wait timer
C-4
Range
0 - 9999999
0.0 - 25.5 (sec.)
0 – 255 (times)
0.0 - 25.5 (sec.)
0.0 - 25.5 (sec.)
0.0 - 25.5 (sec.)
0.0 - 25.5 (sec.)
0.1 - 25.5 (sec.)
Default
1
0
0
0
3.0
2
1
0
0.0
0.0
0.0
0.0
0.1