Restart Sequences From Pause - AND Multi Function Weighing Indicator AD-4402 Instruction Manual

Multi function weighing indicator
Table of Contents

Advertisement

7.3.12.
7.3.12.

Restart Sequences from Pause

Restart Sequences from Pause
7.3.12.
7.3.12.
Restart Sequences from Pause
Restart Sequences from Pause
The restart input was used to start from the point that is stopped in the last sequence.
The control inputs of the function use the preset I/O terminals or OP-05 terminals that
Restart
select
The action of the function is as follows:
When it stopped
During initial dribble flow
During initial medium flow
During full flow
During medium flow
During dribble flow
Waiting batch finish signal
During compensation
During nozzle operation
During mixing
During discharge
During recipe sequence
AD-4402
.
Before the restart
All gates are closed
Stopping the operation
Stopping the mixing
Stopping discharge
According to above list
Action of the restart
Start from initial dribble flow
Start from initial medium flow
Start from medium flow
Start from dribble flow
Start from dribble flow
Waiting batch finish signal
Start from compensation
Start from nozzle operation
Start from the mixing
Start from discharge
According to above list