Request Net Data
When receiving this command, returns the net data immediately.
Template
Command
Reply
Request Tare Data
When receiving this command, returns the tare data immediately.
Template
Command
Reply
Request Accumulated Data
When receiving this command, returns the accumulated data immediately.
Template
Command
Reply
Is Zero
When receiving this command, returns "at zero point" or no immediately.
Template
Command
Reply

13.3.2. Commands to Control the Indicator

Zero Display
Sets the current display to the zero point.
Template
Command
Reply
Tare
Sets the current display to zero of the net data.
Template
Command
Reply
Clear Tare Data
Clears the tare data and displays the gross data.
Template
Command
Reply
AD-4406 Weighing Indicator
RN
R
N
S
T
,
N
T
,
+
0
0
RT
R
T
S
T
,
T
R
,
+
0
0
RA
R
A
Refer to the Fixed data format of "9.2. Display and Operation, Output of
Accumulated Data".
RZ
R
Z
When at ZERO
1
MZ
M
Z
M
Z
MT
M
T
M
T
CT
C
T
C
T
1
2
3
.
0
k
g
1
2
3
.
0
k
g
0